1. The high-efficiency pulverizer is placed in a relatively stable place (the adjustment feet can be adjusted horizontally), and the surrounding environment should be clean, dry and ventilated.
2. The direction of rotation of the motor must be the direction of the arrow marked by the cover.
3. Before starting the machine, it is necessary to check whether there is any foreign matter in the host cavity. Before the material is crushed, it must be inspected first. No impurities are allowed in the material.
4. Regularly check whether the fixing nut of the movable toothed disc is loose and all the fastening parts must not be loose. In particular, check the screws inside the fixed sprocket.
5. Lubrication: Wherever the oil cup is installed, the appropriate lubricating oil should be injected before starting the machine. For continuous work, the number of refueling should be increased appropriately. The actual working time is over 300 hours, and the new lubricating oil must be replaced after cleaning the spindle bearing cavity.
6. When replacing consumable parts and rolling bearings, pay attention to the use of technical screw holes. The operation should be carried out by the repairman familiar with the machine. If the user's operation is difficult, please contact the factory in time, do not arbitrarily dismantle.