Top-Selling Cardiac Defibrillator for Hospital Use

Model NO.: PT-9000C
NIBP Method: Automatic Oscillation
Working Mode: Manual/Automatic
Pediatric: 10-200mmhg: Neonatal: 10-135mmhg
Trademark: seeuco
Transport Package: Standard Packing
Specification: CE
Origin: Jiangsu China
HS Code: 9018909010

 
 

PT-9000C Defibrillator
 

ECG: 
ECG lead: I, II, III, a VR, a VL, a VF, V1-V6 
S-T segment analysis: 2.0-2.0mv 
Protection: withstand 4000v AV/50HZ voltage in isolation and work against electrosurgical interfere and defibrillation. 
ECG lead/cable: general lead/cable for adult, pediatric and neonatal patients

NIBP: 
Method: automatic oscillation 
Working mode: manual/automatic 
Measure: adult: 10-250mmHg 
pediatric: 10-200mmHg 
neonatal: 10-135mmHg

TEMP: 
Measurement range: 20-45°C 
Resolution: 0.1°C

SpO2: 
Display: SpO2 value, pulse histogram, waveform, pulse 
Range: 0-99% for adult, pediatric and neonatal patients 
Probe: adult finger clip(standard) 
Optional: pediatric Y-type clip and neonatal wrap 
Pulse: 
Pulse range: 0-300bpm 
Pulse accuracy: ±2bpm

Defibrillator: 
7 inch TFT display 
SYNC and Non-synchronizer: outlife defibrillator 
Sine wave: monophonic technology 
Energy: 0, 20, 50,100,160,250,300,360 joule 
Charging time: at 360J less than 10sec 
Paddle options: reusable external adult and infant paddles

Power: 
Main power (AC) and built-in battery

 Trade Term
 1. This offer is valid with 30 days.
 2. Delivery time: In 5 working days on confirming the payment
 3. Item of payment: T/T in advance, LC, Western Union
 4. Package: Cartons with foams inside and wooden case for sea shipping
 
Delivery detail:
1.We ship goods by DHL express which is door to door, you donot need to go out can getPA-900BII CE medical Portable ambulances ventilator,takes 3~ 5 days to arrive;
 
2.We can also help you ship PA-900BII CE medical Portable ambulances ventilator by air cargo which you need to go to Air port to take PA-900BII CE medical Portable ambulances ventilator ,it takes about 2-7 days to arrive ;
 
3.If goods are in large quantity and you donot need PA-900BII CE medical Portable ambulances ventilator  so urgently ,you can choose by sea to save some freight cost which takes about one month to arrive .
 
No matter what delivery way, depending on your actual requirements.
 
Our services:
1. For all your inquires about us or our PA-900BII CE medical Portable ambulances ventilator, we will reply to you in details within 24 hours
 
2. We own well-tranied and passional sales & after- sale service who can speak fluent Engligh language
 
3. We offer OEM services. Can print your own logo on PA-900BII CE medical Portable ambulances ventilator, can customize the retail box packing and other things.
 
4. We have very experienced engineers, who can help you better use PA-900BII CE medical Portable ambulances ventilator
 
Our contact details:
 We got several kinds of communicate ways, just hope to keep good touch with you

Vtm Sampling Tube With Swab

[Sample requirements]
The collected nasopharyngeal swab samples should be transported at 2°C to 8°C and sent for inspection immediately, and the sample delivery and storage time should not exceed 48 hours.

[Testing method]
1. Before sampling, mark the relevant sample information on the label of the sampling tube.
2. According to different sampling requirements, use a sampling swab to sample in the nasopharynx.
3. The specific sampling methods are as follows:
a) Nasal swab: Gently insert the swab head into the nasal palate, stay for a while and then slowly turn to exit. Wipe the other nostril with another swab, immerse the swab head in the sampling solution, and discard the tail.

b) Pharyngeal swab: Wipe bilateral pharyngeal tonsils and posterior pharyngeal wall with a swab, also immerse the swab head in the sampling solution, and discard the tail.

4. Quickly put the swab into the sampling tube.
5. Break the part of the sampling swab higher than the sampling tube, and tighten the tube cover.
6. Freshly collected clinical specimens should be transported to the laboratory within 48 hours at 2°C to 8°C.

[Explanation of test results]
After the sample is collected, the sampling solution turns slightly yellow, which will not affect the nucleic acid test result.

[Limitations of the test method]
1. For samples that are seriously contaminated due to improper storage after collection, the final test results will be affected.
2. If the sample is not stored at the specified temperature, the final test result will be affected.


Vtm Sampling Tube With Swab,Disposable Collection Tube Of Virus Samples,Hi Media Vtm Kit,Amylase Sample Collection Tube

Jilin Sinoscience Technology Co. LTD , https://www.jilinsinoscience.com